Scope RFI is a fast and convenient online form to help determine the right scope solution
(hardware, options, software, probes, and accessories) for your current or future applications.
Your selected Scope RFI preferences generate:
Your scope specification summary page
An email quotation of the LeCroy scope and options that best match your Scope RFI
Technology AreaApplications Requiring a Scope
(check each that apply)
Analog Signal Debugging
Digital Signal Debugging
Signal Data Acquisition
Signal Integrity (Rise, Fall, Amplitude, Shape, Mask, Eye)
TDR S-Parameters
Automated Measurements
Partial/Full Automated Testing (Compliance, Device Qualification, Verification, Limit, Worst Case)
Jitter Measurements (Clock, Data, Skew, Time Interval Error, Stress)
Serial Data Analysis - (PCI-E, SAS/SATA, UWB, Ethernet, USB, HDMI, etc.)
Remote Control and Viewing
Preferred Scope Form Factor Real Analog Bandwidth (No DSP Boost)
(RT = Real Time Single Shot SS = Sampling Scope ~ Repetitive Waveforms Required)
Number of Analog Scope Channel InputsNumber of Digital Scope Channel Inputs
Note:
Digital lines can be used for scope triggering or viewed with a time correlated analog trigger input
Maximum Sample Rate on 1 ChannelMaximum Sample Rate on 2 ChannelsMaximum Sample Rate on 4 ChannelsMaximum Memory Depth @ Maximum Sample RateLongest Single Recording Time @ Maximum Sample Rate
Note:
Sample Rate * Memory Depth = Recording Time
1/recording time = lowest frequency detected for jitter and FFTs
Highest Pk-Pk Voltage Expected to MeasureLowest Pk-Pk Voltage Expected to MeasureProbes and Number Required
(check all that apply and number required)
Passive Voltage Probes
High Voltage Probes
Current Probe
Active FET Voltage Single Ended
Active Differential (lvds)
Active High Voltage Differential
O to E Converter
Serial Decode/Triggering
(check all that apply)
I2C
SPI
RS-232
Canbus
Customized Decoding
Measurements Required
(check all that apply)
Standard Horizontal (Frequency, Period, Width, Rise, Fall)
Standard Vertical (Amplitude, RMS, Maximum, Minimum)
Set Up and Hold
Power
Jitter
Skew
Jitter Components (Tj, Rj, Dj)
Statistics - Worst Case, Best Case, Mean, Standard Dev.
Response Times (PLLs, Settling, etc.)
Custom (Unique or proprietary algorithm)
Parameter Math (e.g. RMS of Channel 1 / RMS of Channel 2)
Automated Measure/Feature Find in Waveform (WaveScan)
Waveform Math/DSP Functions
(check all that apply)
Averaging
Standard Math (+, -, *, /)
FFT
Trending (Plotting Measurements over Time)
Tracks (Plotting Measurements as an amplitude over region taken
Histograms (Statistical Distributions)
Chained Math - (Sequential math functions before next trigger)
Response Times (PLLs, settling, etc.)
Eye/Mask
Number of Scopes RequiredModel Currently in Use or in ConsiderationPurchase PlanComments - Important IssuesMonth Required
Thank you.
A quotation will be prepared and sent to your email address.
The next page you see will be your summary of specifications and preferences.
(Use your browser to page back to here from the summary page for edits.)
Please contact me if you have any questions or suggestions.
Best regards,
John Seney (wd1v/fn42)
Northeast Region LeCroy Sales Engineer
Cell 617 686-9882
John.Seney@lecroy.com